|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Protein Dialysis & Desalting |
|
|
|
|
|
|
|
|
|
|
(click for =>) |
"Sample Preparation Catalog of Items - Handbook & Selection Guide" |
|
|
|
|
|
|
|
|
|
For technical
product data sheets please request info by mail to
info@cellconcepts.de |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dialysis Systems |
|
|
|
|
|
|
|
|
|
|
|
Tube‐O‐DIALYZER™
is a mini dialysis system for small sample volumes (20µl‐2.5ml) that
ensures 100% sample recovery, even if precipitation occurs.
Tube‐O‐DIALYZER™ is based on a patented tube design that permits
easy sample handling and a dialysis cap. Simply pipette your sample into the
Tube‐O‐DIALYZER™ tube, seal with the Tube‐O‐DIALYZER™
dialysis cap and invert in your dialysis solution and
dialyze. Following dialysis, briefly centrifuge the complete
Tube‐O‐DIALYZER™ for five seconds and collect 100% of your
sample. For storage of the dialyzed sample, replace the dialysis
cap with the supplied storage caps.
Tube‐O‐DIALYZER™ consists of a regenerated cellulose dialysis
membrane, a neutral non binding dialysis membrane, with Molecular Weight Cut
Offs (MWCO) of 1,000, 4,000, 8,000, 15,000, or 50,000 Daltons. |
|
|
|
|
|
|
|
|
|
|
Article No. |
Description |
Size |
L-Price / Size |
|
|
|
|
|
|
|
|
|
Tube-O-Dialyzer |
|
|
|
|
|
|
|
|
|
|
G-786-610 |
Tube-O-DIALYZER, Micro, 1K
MWCO |
20 |
on quote |
|
|
G-786-611 |
Tube-O-DIALYZER, Micro, 4K
MWCO |
20 |
on quote |
|
|
G-786-612 |
Tube-O-DIALYZER, Micro, 8K
MWCO |
20 |
on quote |
|
|
G-786-613 |
Tube-O-DIALYZER, Micro, 15K
MWCO |
20 |
on quote |
|
|
G-786-614 |
Tube-O-DIALYZER, Micro, 50K
MWCO |
20 |
on quote |
|
|
|
|
|
|
|
|
G-786-615 |
Tube-O-DIALYZER, Medi, 1K
MWCO |
20 |
on quote |
|
|
G-786-616 |
Tube-O-DIALYZER, Medi, 4K
MWCO |
20 |
on quote |
|
|
G-786-617 |
Tube-O-DIALYZER, Medi, 8K
MWCO |
20 |
on quote |
|
|
G-786-618 |
Tube-O-DIALYZER, Medi, 15K
MWCO |
20 |
on quote |
|
|
G-786-619 |
Tube-O-DIALYZER, Medi, 50K
MWCO |
20 |
on quote |
|
|
|
|
|
|
|
|
G-786-620 |
Tube-O-DIALYZER, Mixed, 1K
MWCO |
20 |
on quote |
|
|
G-786-621 |
Tube-O-DIALYZER, Mixed, 4K
MWCO |
20 |
on quote |
|
|
G-786-622 |
Tube-O-DIALYZER, Mixed, 8K
MWCO |
20 |
on quote |
|
|
G-786-623 |
Tube-O-DIALYZER, Mixed, 15K
MWCO |
20 |
on quote |
|
|
G-786-624 |
Tube-O-DIALYZER, Mixed, 50K
MWCO |
20 |
on quote |
|
|
|
|
|
|
|
|
|
Tube-O-Concentrator |
|
|
|
|
|
|
|
|
|
|
G-786-625 |
Tube-O-CONCENTRATOR™ for
20-250μl volumes |
5 |
on quote |
|
|
G-786-626 |
Tube-O-CONCENTRATOR™ for
0.2-2.5ml volumes |
5 |
on quote |
|
|
|
|
|
|
|
|
|
Tube-O-Reactor |
|
|
|
|
|
|
|
|
|
|
G-786-024-4K |
Tube-O-Reactor (Micro),
4kDa MWCO |
5 units |
on quote |
|
|
G-786-024-8K |
Tube-O-Reactor (Micro),
8kDa MWCO |
5 units |
on quote |
|
|
G-786-024-15K |
Tube-O-Reactor (Micro),
15kDa MWCO |
5 units |
on quote |
|
|
|
|
|
|
|
|
G-786-027-4K |
Tube-O-Reactor (Medi), 4kDa
MWCO |
5 units |
on quote |
|
|
G-786-027-8K |
Tube-O-Reactor (Medi), 8kDa
MWCO |
5 units |
on quote |
|
|
G-786-027-15K |
Tube-O-Reactor (Medi),
15kDa MWCO |
5 units |
on quote |
|
|
|
|
|
|
|
|
|
Dialyzer-Enhance |
|
|
|
|
|
|
|
|
|
|
G-786-627 |
Dialyzer-Enhance |
50 ml |
on quote |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tube-O-Dialyzer Accessories |
|
|
|
|
|
|
|
|
|
|
Article No. |
Description |
Size |
L-Price / Size |
|
|
|
|
|
|
|
|
G-786-145 |
Tube-O-Dialyzer Centrifuge
Tube Adapter |
2 |
on quote |
|
|
G-786-145A |
Tube-O-Array |
1 Kit |
on quote |
|
|
G-786-145B |
Stirring Balls |
500 |
on quote |
|
|
G-786-145C |
Micro Dialysis Cups |
12 |
on quote |
|
|
|
|
|
|
|
|
G-786-145D |
Tube-O-Tanks, small |
1 |
on quote |
|
|
G-786-145E |
Tube-O-Tanks, large |
1 |
on quote |
|
|
|
|
|
|
|
|
G-786-141F |
Tube-O-Dialyzer Floats,
micro |
6 |
on quote |
|
|
G-786-142F |
Tube-O-Dialyzer Floats,
medi |
6 |
on quote |
|
|
G-786-149 |
Tube-O-Dialyzer Floats,
micro for Dialysis Cups |
12 |
on quote |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Desalting & Buffer
Exchange |
|
|
|
|
|
|
|
|
|
|
|
The SpinOUT™ GT-100, GT-600
and GT-1200 columns are versatile, spin-format columns for the desalting and
buffer exchange of peptide, protein and nucleic acid solutions ranging from
5µl to 4ml sample volumes. |
|
|
|
|
|
The SpinOUT™ columns are
available in three MWCO sizes for >700, >6,000 or >30,000 Dalton
peptides or proteins and are suitable for samples containing as little as
20µg protein/ml. |
|
|
|
|
|
The SpinOUT™ columns are
easy to use; simply apply the protein sample and centrifuge to recover
proteins and nucleic acids with the column retaining more than 95% of the
salts and small molecules (<100Da for SpinOUT™ GT-100, <1,000Da
for SpinOUT™ GT-600 and <1,500Da
for SpinOUT™ GT-1200). |
|
|
|
|
|
|
|
|
|
|
Article No. |
Description |
Size |
L-Price / Size |
|
|
|
|
|
|
|
|
|
Spin-Out Columns for
Proteins & Peptides & Nucleic Acids |
|
|
|
|
|
|
|
|
|
|
|
Spin-OUT™ GT-100 is for the purification of peptides and
proteins >700Da. |
|
|
|
|
|
|
|
|
|
|
G-786-865 |
SpinOUT™ GT-100, 0.1ml |
25 col |
on quote |
|
|
G-786-866 |
SpinOUT™ GT-100, 1ml |
10 col |
on quote |
|
|
G-786-867 |
SpinOUT™ GT-100, 3ml |
10 col |
on quote |
|
|
G-786-868 |
SpinOUT™ GT-100, 5ml |
5 col |
on quote |
|
|
G-786-869 |
SpinOUT™ GT-100, 10ml |
5 col |
on quote |
|
|
|
|
|
|
|
|
|
Spin-OUT™ GT-600 is for the purification of
proteins >6kDa and nucleic acids larger than 10bp. |
|
|
|
|
|
|
|
|
G-786-703 |
Spin-Out GT-600, 0,1ml |
25 col |
on quote |
|
|
G-786-170 |
Spin-Out GT-600, 1ml |
10 col |
on quote |
|
|
G-786-171 |
Spin-Out GT-600, 3ml |
10 col |
on quote |
|
|
G-786-704 |
Spin-Out GT-600, 5ml |
5 col |
on quote |
|
|
G-786-705 |
Spin-Out GT-600, 10ml |
5 col |
on quote |
|
|
|
|
|
|
|
|
|
Spin-OUT™ GT-1200 is for
the purification of proteins >30kDa and removal of molecules >1,500Da.
The columns are ideal for separating proteins from peptides. |
|
|
|
|
|
|
|
|
|
|
G-786-706 |
Spin-Out GT-1200, 0,1ml |
25 col |
on quote |
|
|
G-786-172 |
Spin-Out GT-1200, 1ml |
10 col |
on quote |
|
|
G-786-173 |
Spin-Out GT-1200, 3ml |
10 col |
on quote |
|
|
G-786-707 |
Spin-Out GT-1200, 5ml |
5 col |
on quote |
|
|
G-786-708 |
Spin-Out GT-1200, 10ml |
5 col |
on quote |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Spin-Out Columns for
PCR |
|
|
|
|
|
|
|
|
|
|
|
The SpinOUT™ PCR columns
are spin format desalting columns that have the ability to remove salts,
radioisotpes, dyes, primers and deoxynucleotides (dNTPs) for nucleic
acids following PCR. Two sizes are available: |
|
|
|
|
|
|
|
|
|
|
|
SpinOUT™ PCR-20: For
rapid purification of PCR products (>100 bp) from unincorporated primers
(<20-mers) and nucleotides using spin-column format. |
|
|
|
|
|
|
|
|
|
|
G-786-174 |
Spin-Out PCR-20 |
10 |
on quote |
|
|
|
|
|
|
|
|
|
SpinOUT™ PCR-32: For rapid
purification of PCR products (>200 bp) from unincorporated primers
(<32-mers) and nucleotides using spin-column format. |
|
|
|
|
|
|
|
|
|
|
G-786-175 |
Spin-Out PCR-32 |
10 |
on quote |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Quoted L-Prices (List-Prices) are in € net, exw
CELL CONCEPTS GmbH + VAT . |
|
|
|
|
Prices are subject to change without prior
notice and not addressed to endusers in the legal sense of price regulation. |
|
|
|
|
|
|
|
|
Copyright © CELL CONCEPTS GmbH 1992 - 2018 &
GBiosciences Inc. 2018 |
19.07.2018 |
(vs02.18) |
|
|
|
|
|
|
|